Open the Minerallum calculator
This example manually verifies the main outputs of the Minerallum calculator.
All values are fictional and are used only to explain the method.
Starting data
Assume a simple two-phase slurry:
- solid particles;
- carrier liquid;
- no significant entrained air.
Inputs:
Solids by mass:
Slurry volumetric flow:
Step 1 - calculate slurry density
Substitute:
Terms:
Sum:
Therefore:
Result:
Step 2 - calculate solids by volume
Therefore:
This immediately shows why 40 wt% is not 40 vol%.
Step 3 - verify density using the volume-fraction form
Solid contribution:
Liquid contribution:
Total:
The same density is recovered.
Step 4 - total slurry mass flow
or:
Step 5 - dry-solids flow
or:
Step 6 - cross-check dry-solids flow from volume fraction
The independent form gives the same result.
This is a useful software invariant.
Step 7 - liquid mass flow
or:
Step 8 - mass closure
The total slurry mass flow closes.
Step 9 - phase volume flows
Solids:
Liquid:
Check:
Step 10 - dilution ratio
The example contains 1.5 units of liquid mass per unit dry-solids mass.
Results summary
| Quantity | Result |
|---|---|
| Slurry density | 1331.6583 kg/m³ |
| Solids by mass | 40.0000% |
| Solids by volume | 20.1005% |
| Liquid by mass | 60.0000% |
| Liquid by volume | 79.8995% |
| Total slurry mass flow | 133.1658 t/h |
| Dry-solids flow | 53.2663 t/h |
| Liquid mass flow | 79.8995 t/h |
| Solid volume flow | 20.1005 m³/h |
| Liquid volume flow | 79.8995 m³/h |
| Dilution ratio | 1.5 |
Reverse check: recover 40 wt% from slurry density
Now assume we know:
ρs = 2650 kg/m³ρl = 1000 kg/m³ρm = 1331.658291457 kg/m³
Use:
Substituting returns:
or:
The forward and inverse calculations are consistent.
Why this does not size a pump
The example provides:
- densities;
- concentration;
- volumetric flow.
It does not necessarily provide:
- viscosity;
- rheology;
- particle-size distribution;
- deposition velocity;
- pipe friction;
- pipe diameter/length;
- elevation;
- NPSH;
- entrained gas.
It would therefore be incorrect to convert this calculation into a pump or pipeline recommendation.
Minerallum deliberately keeps the tool limited to composition and derived flows.
Entrained-air warning
If the measured density contains a significant gas void fraction, it can be lower than the true solid-liquid slurry density.
This example contains no gas phase.
Do not blindly use an aerated bulk-density measurement as ρm in this two-phase calculation.
Privacy
The intended Minerallum implementation performs the calculation locally.
Technical input values are not stored by Minerallum or transmitted to analytics.
The contact CTA does not automatically carry the user’s calculation data.
References
- Wills, B. A.; Finch, J. Wills’ Mineral Processing Technology, 8th edition, Chapter 3. https://doi.org/10.1016/C2010-0-65478-2
- Scelzo, M. T. et al. (2021). Design and validation of a capacitance-based sensor for slurry density measurement. https://doi.org/10.1016/j.expthermflusci.2020.110299
- Bamberger, J. A.; Greenwood, M. S. (2004). Using ultrasonic attenuation to monitor slurry mixing in real time. https://doi.org/10.1016/j.ultras.2004.02.016
Use the calculator
Enter your own phase densities and known concentration/density.
Open Show calculation to inspect every substitution.
This guide uses fictional values and is not equipment sizing, process validation or engineering approval.